GLSV-ZNH1-12
Smart High-Speed Circuit Breaker

GLSV‑ZNH1‑12 Smart High-Speed Circuit Breaker is a high‑performance indoor vacuum circuit breaker designed specifically for 12 kV nonlinear load applications. It supports precise phase‑selection control and provides phase‑controlled switching, non‑full‑phase operation, and anti‑pumping protection, effectively suppressing inrush currents and transient impacts.

It adopts a three‑phase independent permanent‑magnet operating mechanism, achieving ±0.5 ms high‑precision closing and opening control. With a compact structure and mechanical endurance exceeding 30,000 operations, it ensures long‑term reliability.

The breaker is equipped with intelligent features such as event recording, operation waveform capture, and coil monitoring. An integrated energy‑storage module enables low‑power operation, and manual mechanical tripping is supported. It is ideal for medium‑voltage systems requiring highly reliable control of critical loads.


Main Functions
  • (1)
    Phase-Controlled Switching for Nonlinear Loads
  • (2)
    Non-Full-Phase Operation Capability
  • (3)
    Anti-Pumping Function
  • (4)
    Event Logging Function
  • (5)
    Operation Waveform Recording
  • (6)
    Online Monitoring of Closing/Opening Coil Circuit Integrity
  • (7)
    Manual Mechanical Trip Capability
KEY Features
  • 1
    Phase-Selective Switching
    Enables any switching strategy through separate phase control using a permanent magnet operating mechanism
  • 2
    High Precision Timing
    Ensures consistent operation with action time dispersion within ±0.5 ms under all conditions
  • 3
    Robust Mechanics
    Robust mechanical design with a lifespan of no less than 30,000 operations
  • 4
    Manual Trip Capability
    Supports mechanical manual trip operation regardless of power status
  • 5
    Low Power Operation
    Operates with external power current under 0.5 A, ensuring low energy consumption during operation
SPECIFICATIONS
  • Rated Voltage
    12 kV
  • Rated Current
    630 A, 1250 A, 1600 A, 2000 A, 2500 A, 3150 A, 4000 A
  • Rated Short-Circuit Breaking Current
    20 kA, 25 kA, 31.5 kA, 40 kA
  • Closing/Opening Control Voltage
    220 V DC/AC
  • Opening/Closing Time Deviation
    Within ±0.5 ms
  • Mechanical Endurance
    M2
  • Electrical Endurance
    E2